CHYZN - 27F-455-D,DRY STORAGE BATTERY (NO ELECTROLYTE ADDED)

  • MSDS: CHYZN
  • Manufacturer: EXIDE CORP
  • Product Name: 27F-455-D,DRY STORAGE BATTERY (NO ELECTROLYTE ADDED)
  • National Stock Number: 6140-00-984-0147
Product Identification

Product ID:27F-455-D,DRY STORAGE BATTERY (NO ELECTROLYTE ADDED)
MSDS Date:04/01/1998
FSC:6140
NIIN:00-984-0147
Status Code:A
MSDS Number: CHYZN

Responsible Party
EXIDE CORP.
645 PENN STREET
READING, PA 19601-4205
US

Emergency Phone: 610-378-0500/800-424-9300(CHEMTREC)

Info Phone: 610-378-0500

Cage: MO432

Contractor
OCEANOGRAPHIC BATTERY CO INC
PHILDELPHIA, PA 19115 US

Telephone: 215-969-6773

Cage: 0C4E0

Ingredients

LEAD (SARA 313) (CERCLA)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 92-93%

OSHA PEL SEE 1910.1025

ACGIH TLV: 0.05MG/M3, A3; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA 313) (CERCLA)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0.2%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG (SB)/M3; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ARSENIC (SARA 313) (CERCLA)

CAS: 7440-38-2

RTECS: CG0525000

Fraction By Weight: 0.003%

OSHA PEL SEE 1910.1018

ACGIH TLV: 0.01 MG/M3, A1; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


CALCIUM

CAS: 7440-70-2

RTECS: EV8040000

Fraction By Weight: 0.02%


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 0.06%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9596


POLYPROPYLENE

CAS: 9003-07-0

RTECS: TR5000000

Fraction By Weight: <6-<8%


HARD RUBBER

Fraction By Weight: <6-<8%

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HAZARDOUS EXPOSURE CAN OCCUR ONLY WHEN
LEAD IS HEATED ABOVE MELTING POINT, OXIDIZED, OR OTHERWISE
PROCESSED OR DAMAGED TO CREATE DUST, VAPOR, OR FUME. EYES:
IRRITATION. SKIN: NOT ABSORBED THROUGH SKIN . INHALATION: LEAD DUST
OR FUME MAY CAUSE IRRITATION OF UPPER RESPIRATORY TRACT AND LUNGS.
INGESTION: SYSTEMIC TOXICITY.
Explanation of Carcinogenicity:DRY BATTERY NOT CARCINOGENIC.LEAD LISTED
AS A2B CACINOGEN.ARSENIC CARCINOGEN ONLY AFTER PROLONGED,HIGH LEVEL
EXPOSURE.
Effects of Overexposure:ACUTE: LEAD COMPOUNDS: SYMPTOMS OF TOXICITY
INCLUDE HEADACHE, FATIGUE, ABDOMINAL PAIN, LOSS OF APPETITE,
MUSCULAR ACHES AND WEAKNESS, SLEEP DISTURBANCES AND IRRITABILITY.
CHRONIC: LEAD COMPOUNDS: ANEM IA,NEUROPATHY,PARTICULARLY OF MOTOR
NERVES,WITH WRIST DROP,KIDNEY DAMAGE,REPRODUCTIVE CHANGES IN BOTH
MALES AND FEMALES.
Medical Cond Aggravated by Exposure:LEAD AND ITS COMPOUNDS CAN
AGGRAVATE SOME FORMS OF KIDNEY, LIVER AND NEUROLOGIC DISEASES.

First Aid

First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER. GET MEDICAL
ATTENTION. SKIN: WASH AREA WITH SOAP AND WATER. INHALATION: MOVE TO
FRESH AIR, GARGLE, WASH NOSE AND LIPS. GET MEDICAL ATTENTION.
INGESTION: GET ME DICAL ATTENTION.

Fire Fighting

Extinguishing Media:ANY FIRE EXTINGUISHER MEDIA MAY BE USED.
Fire Fighting Procedures:WEAR FULL BODY PROTECTIVE CLITHING AND
SELF-CONTAINED BREATHING APPARATUS WITH POSITIVE PRESSURE AND FULL
FACE PIECE.
Unusual Fire/Explosion Hazard:TO AVOID FIRE/EXPLOSION RISK DURING
CHARGING,KEEP SPARKS/OTHER SOURCES OF IGNITION AWAY FROM BATTERIES
AND DO NOT ALLOW METALLIC MATERIALS TO CONTACT TERMINALS.

Accidental Release

Spill Release Procedures:LEAD DUST OR PARTICULATE SHOULD BE VACUUMED
(USING HEPA FILTER) OR WET-SWEPT; USE CONTROLS WHICH MINIMIZE
FUGITIVE EMISSIONS. DO NOT USE COMPRESSED AIR. PLACE IN DRY, CLOSED
CONTAINERS FOR DISPOSAL OR RECYCING.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE BATTERIES IN COOL, DRY, WELL
VENTILATED AREAS. BATTERIES SHOULD BE STORED UNDER ROOF FOR
PROTECTION AGAINST ADVERSE WEATHER CONDITIONS.
Other Precautions:SEPARATE FROM INCOMPATIBLE MATERIALS. STORE AND
HANDLE ONLY IN AREAS WITH ADEQUATE WATER SUPPLY. AVOID DAMAGE TO
CONTAINERS. KEEP AWAY FROM FIRE, SPARKS, AND HEAT. PRECAUTIONARY
LABELLING: POISON-CAUS ES SEVERE BURNS.

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS.
Ventilation:STORE AND HANDLE IN DRY, VENTILATED AREA.
Protective Gloves:ACID RESISTANT AND GAUNTLET WHEN FILLING
Eye Protection:CHEMICAL GOGGLES/FACE SHIELD WHEN FILING
Other Protective Equipment:WEAR FULL-BODY COVERING DURING USE. WHEN
FILING USE ACID RESISTANT APRON.SEVERE CONDITIONS,WEAR
ACID-RESISTANT CLOTHING.
Work Hygienic Practices:WASH AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
U.S.DOT:DRY BATTERIES(CONTAINING NO ELECTROLYTE)ARE NOT REGULATED BY
U.S.DOT AS HAZARDOUS MATERIAL. RCRA: DRY CHARGE/SPENT LEAD-ACID
BATTERIES ARE NOT REGULATED AS HAZARDOUS WASTE WHEN RECYCLED. HANDL
E ACID FILLED BATTERIES CAUTIOUSLY. MAKE SURE VENT CAPS ARE ON
SECURELY. WEAR PROTECTIVE CLOTHING WHEN FILLING/HANDLING.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>2516F,>138
Melt/Freeze Pt:M.P/F.P Text:486 TO 680F
Spec Gravity:9.6 TO 11.3
Evaporation Rate & Reference:<1, (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLUISH GRAY METAL. NO APPARENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
LEAD: AVOID ACIDS,BASES,HALIDES,HALOGENATES,POTASSIUM
NITRATE,PERMANGANATE,PEROXIDES,NASCENT HYDROGEN,REDUCING AGENTS.
Stability Condition to Avoid:PROLONGED OVERCHARGE, SOURCES OF IGNITION,
WATER DAMAGE, PHYSICAL DAMAGE.
Hazardous Decomposition Products:LEAD:MELTING POINT MAY PRODUCE METAL
FUME,VAPOR,DUST.CONTACT WITH ACID/BASE OR NASCENT HYDROGEN MAY
GENERATE ARSINE GAS.

Disposal

Waste Disposal Methods:DISPOSE OF TOXIC SUBSTANCE IN ACCORDANCE WITH
APPROVED LOCAL, STATE, AND FEDERAL REQUIREMENTS. CONSULT STATE
ENVIRONMENTAL AGENCY AND/OR FEDERAL EPA. USED BATTERIES SHOULD BE
RETURNED TO SMELTER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.